A furnace blowing cold air is most often caused by a thermostat fan set to ON, a clogged filter, a furnace that failed to ignite, a tripped safety switch, or a clogged condensate drain on a high-efficiency unit. Start at the thermostat: set it to HEAT, set the fan to AUTO, and raise the temperature at least 5 degrees above the room. Then check the filter and the power switch.
Cold air usually means the fan is running while the burners are not lit. Most causes are simple, and a few need a technician. This guide covers safe checks and where to stop.
Why is my furnace blowing cold air when the heat is on?
The blower and the burners work separately. The blower moves air through the ducts, and the burners (or electric elements, or a heat pump) warm it. Cold air means the blower is running without heat to carry. These are the common reasons in Los Angeles homes:
Fan set to ON. The blower runs constantly, including between heating cycles, and the air in those gaps feels cold. AUTO runs the fan only while the furnace is heating.
The thermostat is not calling for heat. The mode may be on COOL or OFF, the setpoint may be at or below room temperature, or a smart thermostat may be on a hold, away, or schedule setting.
A dirty filter. A clogged filter chokes airflow, the furnace overheats, and a limit switch shuts the burners off while the fan keeps running. A furnace that sat idle all summer often starts the first cold night with a loaded filter.
The furnace did not ignite. A weak ignitor, a dirty flame sensor, or an out pilot light shuts the burners down while the fan keeps going. This is a technician repair.
A blocked condensate drain. High-efficiency furnaces (vented with white PVC pipe) make water as they run. If the drain clogs, a float switch stops the furnace from firing.
A tripped safety control. The limit, pressure, or rollout switch can lock the furnace out. A repeat lockout needs to be diagnosed.
A failing component. A bad gas valve, control board, blower motor, or a cracked heat exchanger can all leave you with cold air. None of these is a home fix.
Want a straight answer on your system?Most repairs can be estimated free over the phone. Open 24 hours Sunday to Thursday, Friday 9 AM to 3 PM.
Call (310) 469-1979Is it normal for a furnace to blow cold air at first?
Yes, briefly. At startup the ignitor warms, the burners light, and the heat exchanger has to heat up. Many furnaces hold the blower for 30 to 90 seconds so cold air is not pushed through the house. Cool air for a minute or two that then warms up is normal. Air that stays cold after several minutes, or turns cold again, points to a shutdown.
Is it safe to keep running a furnace that blows cold air?
If you smell gas, do not run anything. Leave the house, then call SoCalGas at 1-800-427-2200 from a safe place, or call 911. Do not touch light switches or try to find the source yourself.
With no gas smell, running the fan without heat will not hurt the furnace. A furnace that cycles on and off repeatedly, shows a yellow or rolling flame, makes loud bangs, or keeps tripping a breaker should be turned off at the thermostat until someone looks at it. Do not keep resetting a breaker that will not hold.
What can I check myself?
These checks use only the thermostat, the filter, the switches, and a look at the unit. Do not open gas valves, remove burner covers, or work on the burners or wiring.
Thermostat mode and fan. Set HEAT and fan AUTO. Raise the setpoint at least 5 degrees above the room temperature. Replace batteries if the display is dim, and cancel any hold or away setting. Wait a few minutes.
The filter. Slide it out and hold it to the light. If you cannot see light through it, replace it with the same size, with the arrow pointing toward the furnace.
Breaker and furnace switch. Look for a tripped breaker (it sits in the middle). Switch it fully off, then on once. Then check the switch near the furnace, which looks like a light switch.
The front panel. A small switch inside confirms the panel is closed, and most furnaces will not run without it. Make sure the panel is seated snugly. Do not remove it.
Pilot light, older units only. If your furnace has a standing pilot that is out, follow the relighting instructions printed on the unit only if there is no gas smell and you are comfortable doing it. If it will not stay lit, stop and call.
Condensate drain, high-efficiency units. If water is backed up in the drain line or pooled by the unit, the float switch may have locked the furnace out. Clearing an easy-to-reach clog in the tubing is fine. If the water source is unclear, call.
Vents and returns. Open every supply register and move furniture or boxes away from registers and the return grille.
Give the furnace a few minutes after each check.
Furnace blowing cold air after a filter change?
Usually the new filter is installed backward, is the wrong size, or is not fully seated, which can leave the filter slot or panel open and trip the safety switch. Turn the thermostat down, re-seat the filter with the arrow toward the furnace, close the cover snugly, and try again. If it still blows cold, switch the furnace off at its power switch, wait 30 seconds, and switch it back on.
Furnace blowing cold air at night, or won't shut off?
At night the usual causes are the schedule and the fan setting. A program may lower the setpoint overnight, so heating stops while the fan keeps running. Check that the fan is on AUTO and review the nighttime schedule.
If the furnace will not shut off, the fan may be set to ON, the thermostat may be misreading the room, or a relay or control board may be stuck. Set the thermostat to OFF and the fan to AUTO. If the blower keeps running, turn the furnace off at its power switch and call a technician.
Furnace still blowing cold? Call Cool Breeze LA at (310) 469-1979.
Heat pump blowing cold air in heat mode?
Mode on HEAT, fan on AUTO, a clean filter, and power apply to heat pumps too. Heat pump air is also warmed to a lower temperature than furnace air, so it can feel cool against your skin while still heating the house.
Defrost mode. In cool, damp weather the outdoor coil can frost over. The system briefly reverses to melt it, and you may feel cool air and see steam outside. It should last a few minutes.
Real problems. A refrigerant leak, a failed reversing valve, or a failed compressor leaves the air cold. Ice that stays on the outdoor coil, or an outdoor unit that is not running, is worth a call.
Do not chip ice off the coil or pour hot water on it. Turn the system off and call.
When should I call a technician?
Call if the checks above did not fix it, or if any of these apply:
You smell gas (leave first, then call SoCalGas at 1-800-427-2200 or 911).
The furnace starts, runs briefly, and shuts down again, over and over.
A breaker trips again right after you reset it.
You see a yellow or rolling flame, soot, or water around the furnace, or hear loud banging.
A carbon monoxide alarm sounds (get everyone outside and call 911).
A technician can check the ignitor, flame sensor, limit and pressure switches, blower, and gas pressure, and can test the heat exchanger. See our heating repair in Los Angeles page for what we handle. If it is a cold night with no heat, our emergency HVAC service in Los Angeles page has the details. We are open 24 hours Sunday to Thursday, Friday 9am to 3pm, and closed Saturday. The diagnostic is $49, and it is included in the repair price if you go ahead with the repair. Cool Breeze LA holds CSLB license #1154105 and serves Los Angeles.
If the furnace will not start at all, read furnace not turning on: 7 checks. A yearly tune-up (see HVAC maintenance in Los Angeles) helps prevent a cold-night breakdown.
Common questions
Why is my furnace blowing cold air instead of heat?
The blower is running while the burners are not producing heat. Common causes are the fan set to ON, a clogged filter that triggered a safety shutdown, a failed ignition, a clogged condensate drain, or a tripped safety switch. Check the thermostat and filter first.
Why does my furnace blow cold air when set to heat?
With the thermostat on HEAT and the setpoint above room temperature, the furnace should start, and cool air for the first minute or two is normal. If it stays cold, the fan may be on ON, or the furnace is failing to ignite or locking out on a safety switch.
Why is my furnace blowing cold air and no heat at all?
Confirm the furnace power switch and breaker are on, the thermostat is on HEAT, and the filter is clean. If those are fine, the furnace is likely failing to light because of a bad ignitor, a dirty flame sensor, a gas supply problem, or a safety lockout. That needs a technician.
Can a dirty filter make a furnace blow cold air?
A dirty filter can make a furnace blow cold air. A clogged filter restricts airflow, the furnace overheats, and the limit switch shuts off the burners while the fan keeps running. Replacing the filter often fixes it, though the furnace may need a few minutes or a power reset to restart.
How much does it cost to fix a furnace that blows cold air?
The cost to fix a furnace that blows cold air depends on the cause, which can range from a filter to a failed part. Cool Breeze LA charges a $49 diagnostic fee to find the problem, and that fee is included in the repair price if you go ahead with the repair. Call (310) 469-1979.